Wednesday, August 6, 2008

WILO: BAC


Glanded pump, monobloc design with screwed or Victaulic connection

For pumping water/glycol mixtures with 20 - 40 Vol-% glycol

Technical data
  • Permitted temperature range -15 °C to +60 °C
  • Mains connection 3~400 V, 50 Hz
  • Protection class IP 54
  • Nominal width: G2/G 1 1/2 or Victaulic connection 60.3/48.3 mm
  • Max. operating pressure 6 bar
Materials
  • Pump housing and lantern: PA 6.6 50% GF
  • Impeller: GFN 3l
  • Shaft: X30Cr13
  • Mechanical seal: Pressure resin impregnated carbon/aluminium oxide/EPDM
Source: www.tiarasakti.co.id

No comments: