Glanded pump, monobloc design with screwed or Victaulic connection
For pumping water/glycol mixtures with 20 - 40 Vol-% glycol
Technical data
- Permitted temperature range -15 °C to +60 °C
- Mains connection 3~400 V, 50 Hz
- Protection class IP 54
- Nominal width: G2/G 1 1/2 or Victaulic connection 60.3/48.3 mm
- Max. operating pressure 6 bar
Materials
- Pump housing and lantern: PA 6.6 50% GF
- Impeller: GFN 3l
- Shaft: X30Cr13
- Mechanical seal: Pressure resin impregnated carbon/aluminium oxide/EPDM